Dmfit Program - Home Page


Compatibility issues


The Dmfit programs enables fitting of solid state (and liquid) NMR spectra, including 1D and 2D datasets
current version is : dmfit#20230120 [Download... ]

The "dmfit" program is is a versatile tool designed for fitting NMR spectra, including solid state NMR. It provides a variety of different models that account for :

  • Gaussian/Lorentzian lines,
  • spinning sidebands,
  • Chemical Shift Anisotropy (static and MAS),
  • first and second order Quadrupolar interaction (static and MAS)
  • ...
New Features...
  • from #20211004 : allows reading Neo Console TopSpin 4 datasets..."
  • from #20200306 : solves a bug leading to crash when "load other fit"
  • from #20191211 : read data with long filenames (>128 characters)...
  • from #20191202 : read double precision TopSpin4.0 format (Neo Consoles)...
  • from #20121202 : create .fmxl from CASTEP .magres Have a look...
  • Error from Monte-Carlo : Have a look...
report bugs on the Bug report page...

Optimisation Algorithm

The mismatch criterion that we use is a simple quadratic distance between the experimental and modelled spectrum. This could of course be improved in some cases but its advantage is to make no hypothesis upon the type of data that we consider. The optimisation algorithm aims at minimizing the mismatch criterion by varying the parameters of the different lines. As the computation of the model includes non-linear dependencies to the different parameters and, in some cases, no simple analytical form, we use an iterative algorithm. Starting with an approximate solution we compute and add an increment to try to converge to a local minimum. This does not ensure the unicity of the obtained solution that will only be the closest to the starting point. The algorithm used in our program is a constraint gradient protocol which involves computation of the partial derivatives over each of the parameters for all variable parameters and each point of the experimental spectrum. The resolution of the n-linear system of equation yields an increment that is finally added to the starting parameter set. This procedure is rather robust when close to a final well defined.

Acknowledgements

Massiot et al. Magnetic Resonance in Chemistry, 40 pp70-76 (2002) [see more or ask for a reprint]
ISI citation index 3446 (12/12/2023)
users : 12222 registered - 11277 with download
users logged in : 22 last week - 83 last month - 975 last year

"One of the most cited recent paper in the field of Engineering" ISI July 2003
we thank all "dmfit" users for this achievement


IR-RMN Tres Hauts Champs provides national and international access to 850 MHz spectrometer at CEMHTI
It is part of the Infranalytics CNRS Infrastructure [NMR / EPR / FT-ICR]
PANACEA brings together and integrates eight national solid-state NMR infrastructures in Europe and in the United States and opens them to all European chemists, from both academia and industry. Funded by the European Commission Horizon 2020 framework program, the project started on September the 1st 2021 for a period of four years.
PANACEA web site / linkedIn / Twitter / Facebook